服務日期 lifting CE服務內容
 

Applicant: CORETRONIC CORP
Standard: UL 583, Electric-Battery-Powered Industrial Trucks, Edition 10, Revision Date 10/30/2020
Scope: 8 models of Motor Speed Controllers, AC F2-T serials, 4 models ;AC F2-D serials, 4 models
Rough Quote: USD $ 30,500 (exclude 5% tax)
File No; CCN: New - YCFT2

UL
這個Project有兩種進行方式可以進行
(1)遠端目擊
(2)將測試樣品和搭建測試所需工具寄送美國NBK實驗室測試。

Assumption:
All safety critical components, enclosures and materials are UL Listed/Recognized and suitable for the intended application.

Quotation does not include fees associated with travel, lodging, meals, etc.

Quotation does not include fees associated with Safety Certificates for other countries.

No alternate components are employed.

Each line item above is a separate phase of the Service(s) and is optional and independent of the completion of the previous phase(s).  Your written acceptance will be required to proceed to the next phase(s) of the Service(s) and each phase will be governed by this Quotation and the referenced terms and conditions.  Final certification, if applicable, is contingent on the successful completion of all phases and compliance with UL Requirements.

This Quote anticipates that all requested information and/or samples necessary to proceed with the evaluation will be available within 60 days from the time they have been requested. 

This Quote includes the cost of a predetermined set of testing.  In the event of testing nonconformance, a summary of the testing results and cost for the additional evaluation will be provided.  A separate project may be issued to cover the retesting.

Additional cost will be required for any change of scope and/or rework, once the project is established.

 
During the course of the evaluation, if requested information and/or samples are unavailable for more than 60 days, preventing work from continuing, we will close the project and bill for the charges incurred.  A new project will be established when all necessary items are available.

This quotation includes representative testing in order to provide a lower project cost limit and reduce sample requirements. Upon completion of the Phase 1 – Construction Review/Pre-Testing, if it is determined additional testing is required, additional costs may be necessary.

Where testing is conducted at Lab outside UL, the client is required to cover the charges for Lab either on their own or as an additional charge above the cost limit. 

This quote excludes costs or fees associated with services of outside contractors or test facilities and certain special equipment charges.  Completion time assumes that the outside contractor and test facilities, when necessary, will be available within the timeframe allotted.

In accordance with UL's Data Acceptance Program (DAP), UL retains the right to request that a test or test program be repeated at UL or under UL witness after review of submitted data. Additional charges may apply.

All test equipment utilized during a factory visit that is provided by the client must have the proper calibration certificates submitted for review and verified for compliance prior to the arrival of the project handler. Please visit http://services.ul.com/service/data-acceptance-program/ for essential information related to witnessing testing at your facility and/or data acceptance issues.

Devices or materials utilized for testing and/or certification must be UL Certified and bear the appropriate UL Mark, while meeting the requirements outlined in the product standard being used for this evaluation. Any device or material that does not conform to these requirements may be subject to additional evaluation, prior to being utilized for testing in this project.

Assumes the client can provide a sample(s) of each (Model AC F2-T Series & AC F2-D Series) unit for evaluation purposes.

 
Assumes the client can provide electrical schematics, voltage maps, and printed wiring board layout drawings (in English).

Assumes the client can provide adequate samples to complete all testing required at client's site.

Assumes the client can provided the necessary connections to allow us to function the controller as it is intended in the end use application.

Assumes the following tests to be conducted:

1.) Input Test – Components(Conduct both at DC and AC application)
2.) Temperature Test - Components(Conduct both at DC and AC application)
3.) Dielectric Withstand Test – Components
4.) Solid State Circuitry Test
5.) Low-voltage Limited Energy Circuit Measurements
6.) Ball Impact Tests
7.) Mold Stress Relief Test

Assumes we will test a model from the AC F2-T Series and a model from the AC F2-D Series to represent all models.

Assumes Model AC F2-T 48-240-240 will be tested and used to represent the AC F2-T (Pump) Series.

Assumes Model AC F2-D 48-240 will be tested and used to represent the AC F2-D (Traction) Series.

Assumes no unlisted component evaluations.

TAT: 4-10 weeks

Best Regards,

Lori Chen
Inbound Sales Representative
---------------------------------------------

Energy & Power Technologies Division
UL GmbH, Taiwan Branch
260, Da-Yeh Road, Peitou, Taipei. Taiwan 112
T: +886 2 7737 3404
W: taiwan.ul.com

2021/1/26
  1. UL583: 2020: STANDARD FOR SAFETY Electric-Battery-Powered Industrial Trucks(pdf)
    1. para. 18 :設計間隙要求參考UL840(要先訂9.3Polution 等級)
  2. 競爭對手(Curtis Data sheet)(產品資訊)恆智重工
2021/1/28
  1. 已知台灣的工程部門沒有這本標準的技術能力。
  2. 中國蘇州分公司有L2工程師,但實驗室也沒有測試能力,他說案件都是到客戶端做目擊測試(WTDP)的方式進行。他說美國那邊大都也是這種方式在進行。
  3. 如要知道費用,則須進一步提供產品的樣貌、規格(照片、規格書或說明書)等較詳細一點的資料,以便評估。並進一步聯繫美國那邊有關後續作業的方式。
  4. 服人員Elle Yang,
    聯絡專線電話是02-7737-3729,
    客服部的分機是CS Hotline: 02-7737-3168
  5. Lori Chen
    T: +886 2 7737 3404
    Lori.Chen@ul.com