DOUBLE INSULATED PRODDUCT (CLASS Il)
Double insulated (Class II)雙重絕緣的工具(II類)
.No Grounding Pin on Plug Cap.插頭布袋接地插片.
.Provided with two levels of insulation (Basic and Supplementary)Reinforced insulates may be used in some areas, which will have properties equivalent to Double ululation.提拱2重絕緣(基本絕緣和附加絕緣),在某些地方可以使用與2重絕緣具有相同屬性的加強絕緣.
.lf one level is damaged, the second level will still provide protection to prevent assessable area from becoming live.如果1重絕緣(基本絕緣)受到損害,第2重絕緣可以提供保護,以防止觸金屬部分的帶電體.
0304
05

SAFETY EXTRA LOW VOLTAGE PRODUCT  (CLASS III)安全超低壓產品
Products operated under Safety Extra Low Voltage Supply (Class III)工具供電電源為安全超低電壓電源(SELV)
.Electrical shock is reduce due to operation with the supply of Safety Extra Low Voltage.由於使用安全超低電壓電源,進而避免觸電
.Battery operated with Maximum 30Vdc電池驅動最高電壓為30Vdc 電池驅動最高電壓30Vdc
.Safety Extra Low Voltage is 30Vdc or 42Vpeak安全超低電壓是:低於30Vdc或42V峰值電壓
NON GROUNDED AND NON DOUBLE INSULATED PRODUCTS
.some products are non-grounded and non-double insulated.
.For Example: sewing machine; massager.
.CSA22.2No.68-09Motor Operated Appliances
5.18Bonding and grounding
5.18.1General
Unless double insulate, equipment shall be constructed to comply with CAN/CSA-C22.2No.0.4, except as otherwise specified in Clause5.18.2.    
5.18.2Exceptions
Equipment, other than sprayers, need not comply with Clause 5.18.1where
(a)  Exposed metal parts are not likely to become energized, and the equipment complies with Clause 8.4; or.
(b)  It is cord-connected household equipment that is hand-held or table-mounted and is neither connected do the water supply nor drainage during use nor intended to be immersed partially or entirely for cleaning.

NON GROUNDED AND NON DOUBLE INSULATED PRODUCTS
UL 1647 Motor Operated Massage and Exercise Machines
18 Grounding
18.1 General
18.1.1  An appliance of one or the following types shall have provision for grounding

a)  An appliance for use in damp or wet locations and intended to be used in other than residential occupancies.
b)  An appliance intended to be used on a circuit operating at more than 150 V to ground –see 18.1.3
c)  An appliance intended for permanent connection to the electrical supply.
d)  An appliance intended for outdoor use
e)  An appliance intended for use with water or other liquid.

Exception A cord-connected appliance may be provided with an acceptable means of double insulation in accordance with the applicable requirements in the standard for double insulation systems for use in Electrical Equipment
UL 1097 .  In lieu of grounding.

CANNOT BE GROUNDED
Some products cannot be grounded.
Grounding may cause hazard during reasonable misuse where live parts are readily accessible for its function.
Double pole Switch must be used.
For Example may hold onto the body of toaster and use a knife to pry the bread out from the bread slot and the knife may touch the heating element.