Enclosure REQUIREMENTS 外殼的要求
Purpose of Enclosure.外殼的作用
To prevent access of Hazardous Pats.防止觸及危險部件
. A part, when removed will allow access of Hazardous Parts is
Enclosure . 外殼只當移開她後可以觸及危險部件的部分
. A switch Knob may be an Enclosure .開關的旋鈕可以是外殼
. Tested by test probe per Standard.用安全標準中的規定進行測驗
To prevent fire form spreading from the tool .防止火焰從工具中蔓延出來
. Flame Test requirements. HB, V, 5VA 〈Refer to Appropriate
Standards〉火焰測試要求:HB, V, 5VA〈參加相應標準〉Usually
When HB is used, it also requires HAL and HWI
ENCLOSURE 外殼的要求
. Types of Material 材料的類型
a. Metal Enclosure 金屬外殼
. Material Thickness /Strength 材料的厚度/強度
. Resistance to Rust 抗腐蝕性
b Plastic Enclosure塑料外殼
. Material Flame Rating 材料的燃燒等級
. Material Thickness/Strength 材料的厚度/強度
. Resistance to Deformation 抗變形性
resistance to Moisture抗潮濕
ENCLOSUSRE REQUIREMENTS
RESISTANT TO MOISTURE PER 60745,
Enclosure must provide protection against moisture 〈water
And humidity〉according to IPX classification, specified by
Part 2 of 60745, or by manufacturer.
WATER〈14.1.1 and 14.12〉as per IEC 60529,parts
removed without aid of tools are not energized.
. Most tools are IPZ0 – for ordinary location
. IPX1 and 2 – tested by drip box
. IPX3 and 4 – oscillating tube or shower head
. IPX5 and 6 – spray nozzle
. IPX7 – immersion up to 1m deep
. Water treatment is followed by Electric strength and visual
examination.
ENCLOSURE REQUIREMENTS
HUMIDITY PER 60745
SPILLAGE
. Parts removed without aid of tools.
. 0.25 I or 15% of container is filled with water containing
1% of NaC and poured steadily for 1min.
. Water treatment is followed by Electric Strength and
Visual examination.
After water and/or Spillage and before the Humidity
Treatment, the tool is allowed to stand at the room
Temperature for 24 hours.
ENCLOSURE REQUIREMENTS
HUMIDITY PER 60745
HUMIDITY
. Parts removed without aid of tools.
. Before treatment sample warmed to〈t+4 deg.C〉
. 48 hrs in humidity cabinet @93 +/- 2%, 20 to 30 deg.C
. Immediately after humidity , the LeaKage Current test is
Conducted and followed by the Electric Strength. The
Leakage current limits are doubled if:controls have off in
All poles, tool has no control other than one-shot,
Thermostats hate no off position, and tool has a line filter.






|