Enclosure REQUIREMENTS 外殼的要求


Purpose of Enclosure.外殼的作用

To prevent access of Hazardous Pats.防止觸及危險部件

.  A part, when removed will allow access of Hazardous Parts is
Enclosure . 外殼只當移開她後可以觸及危險部件的部分
.   A switch Knob may be an Enclosure .開關的旋鈕可以是外殼
.   Tested by test probe per Standard.用安全標準中的規定進行測驗

To prevent fire form spreading from the tool .防止火焰從工具中蔓延出來

.   Flame Test requirements. HB, V, 5VA 〈Refer to Appropriate
Standards〉火焰測試要求:HB, V, 5VA〈參加相應標準〉Usually
When HB is used, it also requires HAL and HWI


ENCLOSURE 外殼的要求


.  Types of Material 材料的類型
a.  Metal Enclosure 金屬外殼
.  Material Thickness /Strength 材料的厚度/強度
.  Resistance to Rust 抗腐蝕性
b  Plastic Enclosure塑料外殼
.  Material Flame Rating 材料的燃燒等級
.  Material Thickness/Strength 材料的厚度/強度
. Resistance to Deformation 抗變形性

resistance to Moisture抗潮濕

  ENCLOSUSRE REQUIREMENTS
RESISTANT TO MOISTURE PER 60745,
Enclosure must provide protection against moisture 〈water
And humidity〉according to IPX classification, specified by
Part 2 of 60745, or by manufacturer.

WATER〈14.1.1 and 14.12〉as per IEC 60529,parts
removed without aid of tools are not energized.
.  Most tools are IPZ0 – for ordinary location
.  IPX1 and 2 – tested by drip box 
.  IPX3 and 4 – oscillating tube or shower head
.  IPX5 and 6 – spray nozzle
.  IPX7 – immersion up to 1m deep
.  Water treatment is followed by Electric strength and visual
examination.

 

ENCLOSURE REQUIREMENTS
HUMIDITY PER 60745
SPILLAGE
. Parts removed without aid of tools.
.  0.25 I or 15% of container is filled with water containing
1% of NaC and poured steadily for 1min.
. Water treatment is followed by Electric Strength and
Visual examination.

After water and/or Spillage and before the Humidity
Treatment, the tool is allowed to stand at the room
Temperature for 24 hours.

 ENCLOSURE REQUIREMENTS
HUMIDITY PER 60745

HUMIDITY
. Parts removed without aid of tools.
.  Before treatment sample warmed to〈t+4 deg.C〉 
.  48 hrs in humidity cabinet @93 +/- 2%, 20 to 30 deg.C
. Immediately after humidity , the LeaKage  Current  test is 
Conducted and followed by the Electric Strength. The
Leakage current limits are doubled if:controls have off in
All poles, tool has no control other than one-shot,
Thermostats hate no off position, and tool has a line filter.